Product Overview

The anywAiR Technology Zoneconnex is a flexible, cost-effective Wi-Fi zone control solution designed for compatible GENERAL AIRSTAGE ducted air conditioning systems.

Supporting up to 10 zones, Zoneconnex allows individual airflow management, convenient touchscreen operation and remote access through the anywAiR Zoneconnex mobile app.

Product Video

Watch the following video for an introduction to the anywAiR Zoneconnex system.

 Watch the Zoneconnex video on YouTube 

Key Features and Benefits

10 Zone ControlIndependently turn up to 10 zones on or off and manage airflow throughout the property.
Precise Airflow AdjustmentAdjust zone airflow from 0% to 100% in 5% increments, subject to configured limits.
Wi-Fi ConnectivityControl the system remotely through the compatible iOS or Android mobile app.
Scenes and SchedulingSave preferred operating settings and activate them automatically at scheduled times.
Touchscreen InterfaceWall-mounted 7-inch TouchPoint LCD for everyday air conditioning control.
Optional Room SensorsWireless temperature and humidity sensors can provide room temperature information and an alternative primary sensing location.
Standalone CommissioningInstallers can configure the controller without an active home internet connection.

System Components

Zoneconnex Controller - UTY-ZCAW1

The main control module is installed in the ceiling void and communicates directly with the compatible indoor air conditioning unit through its UART interface.

  • Supports up to 10 compatible 24VAC RJ12 damper motors.
  • Maximum rated motor current: 150mA per motor.
  • 24VAC power supply included.
  • UART connection to indoor unit PCB.
  • RS485 communication to the TouchPoint LCD.
  • LoRa communication for optional wireless sensors.

TouchPoint LCD

The supplied wall-mounted 7-inch touchscreen provides convenient control of the air conditioning system and individual zones.

  • Dimensions: 112mm high x 181mm wide.
  • Powered by the main Zoneconnex controller.
  • Provides air conditioning and zone control.
  • Includes Wi-Fi configuration and system information.
  • Provides access to installer configuration.

Optional Wireless Sensor - TS-ZC1

The optional DROPLET sensor measures room temperature and humidity and communicates wirelessly with the Zoneconnex controller.

  • No sensor wiring required.
  • Up to 10 sensors supported per controller.
  • Multiple sensors assigned to one zone are averaged.
  • A sensor can be designated as the primary temperature sensing point.
  • Room temperatures can be displayed for monitoring.
Important: DROPLET sensors provide temperature and humidity sensing. They do not provide independent temperature-controlled VAV regulation for each zone. Zone airflow is adjusted using the configured damper opening percentage.

Compatible GENERAL AIRSTAGE Systems

Zoneconnex is compatible with selected R32 GENERAL AIRSTAGE ducted indoor units. Confirm the exact indoor model before installation.

System TypeCompatible Indoor Models
High Static DuctedARTH24KHTA
ARTH30KHTA
ARTH36KHTA
ARTH45KHTA
ARTH54KHTA
ARTH60KHTA
ARTH60KHTB
ARTH65KHTA
ARTH72KHTA
ARTH90KHTA
Mid Static DuctedARTH18KMTAP
ARTH24KMTAP
ARTH30KMTAP
ARTH36KMTAP
ARTH45KMTAP
ARTH54KMTAP
Bulkhead DuctedARTH09KLLAP
ARTH12KLLAP
ARTH18KLLAP
ARTH09KSLAP
ARTH12KSLAP
ARTH18KSLAP
Existing Installations: Although an indoor unit may be listed as compatible, the existing ductwork and damper specifications must be assessed by a GENERAL AIRSTAGE Authorised Partner before retrofitting Zoneconnex.

VRF compatibility is not currently confirmed in the supplied compatibility documentation.

Using the TouchPoint Controller

Main Air Conditioning Controls

The home screen allows users to:

  1. Turn the air conditioning system on or off.
  2. Select Auto, Cool, Heat, Fan or Dry mode.
  3. Adjust the temperature setpoint.
  4. Adjust the indoor fan speed, where supported.
  5. View the current temperature if enabled during installation.

Individual Zone Control

  1. Select the Zones icon on the touchscreen.
  2. Locate the room or zone you wish to adjust.
  3. Turn the zone on or off.
  4. Adjust the zone airflow percentage as required.
  5. Repeat for other zones as needed.

Airflow can be adjusted in 5% increments, within the minimum and maximum settings configured by the installer.

Sync Zones

If zone airflow is not responding as expected, the Sync Zones function can be used to reset zone positioning and restore correct airflow.

Scenes and Scheduling

Zoneconnex allows users to create preferred operating arrangements and activate them automatically.

What is a Scene?

A Scene is a saved group of air conditioning settings. It can include:

  • Operating mode.
  • Temperature setpoint.
  • Fan speed.
  • Selected zones and airflow settings.

For example, a user may create a Night Time scene that operates selected bedroom zones at preferred settings.

Creating a Schedule

  1. Open the Schedules screen.
  2. Create or select the Scene you want to use.
  3. Select Create Schedule.
  4. Enter a schedule name.
  5. Select the required days of the week.
  6. Choose the activation time.
  7. Assign the required Scene.
  8. Save and enable the Schedule.

Schedules can automatically activate Scenes at the selected times and days.

Connecting Zoneconnex to Home Wi-Fi

Home Wi-Fi connectivity allows the system to be accessed through the mobile app.

  1. On the TouchPoint LCD, select the Wi-Fi icon.
  2. Select Scan Wi-Fi.
  3. Wait for available wireless networks to appear.
  4. Select the required home Wi-Fi network.
  5. Press Connect.
  6. Enter the Wi-Fi password using the touchscreen keyboard.
  7. Press Connect to confirm.
  8. Verify that the controller displays the connected network details.

Once connected, the screen displays information including signal strength, connection speed, security type, channel and the Home QR code.

Setting Up the anywAiR Zoneconnex Mobile App

The anywAiR Zoneconnex app is available for compatible Apple and Android devices.

Before You Begin

Ensure the TouchPoint LCD is connected to the home Wi-Fi network and your mobile device is connected to the same network during initial setup.

Step 1 - Install the App

Search for anywAiR Zoneconnex in the Apple App Store or Google Play Store.

Step 2 - Create an Account

  1. Open the anywAiR Zoneconnex app.
  2. Select Sign-Up if you are a new user.
  3. Enter your email address and create a password.
  4. Confirm your password and submit the registration.
  5. Enter the verification code sent to your email.
  6. Complete the account verification process.

Existing users can sign in using their registered account credentials.

Step 3 - Add Your Home

  1. Open the Wi-Fi screen on the TouchPoint LCD.
  2. Locate the Home QR code.
  3. In the mobile app, select Scan QR Code.
  4. Scan the Home QR code displayed on the LCD.
  5. Enter a name for the home.
  6. Select Add Home.

The connected system should now appear on the mobile app home screen.

Mobile App Functions

  • Turn the air conditioning system on or off.
  • Adjust operating mode and temperature.
  • Turn individual zones on or off.
  • Adjust zone airflow percentages.
  • Create and manage Scenes.
  • Create and manage Schedules.
  • Invite and manage other household users.
  • Manage multiple Zoneconnex systems.

Installer Information and Commissioning

Qualified Personnel Only

Installation, electrical wiring, system configuration and servicing must be performed by appropriately qualified and authorised personnel. Always isolate the air conditioning system before wiring or servicing.

Package Contents

  • Zoneconnex main controller.
  • TouchPoint LCD.
  • LoRa antenna.
  • 24VAC power supply.
  • 15m four-core 24 AWG LCD communication and power cable.
  • 2m PAP-04V-S UART communication cable.
  • Eight M3 x 25mm self-tapping screws.

Controller Connections

ConnectionFunction
24VAC InputMain controller power supply.
UARTCommunication to indoor PCB via CN65 or CN75, model dependent.
RJ12 Zone PortsConnections for up to 10 compatible 24VAC damper motors.
LCD RS485TouchPoint LCD communication.
LCD Power18VDC supply to TouchPoint LCD.
LoRaWireless DROPLET sensor communication.

Refer to the official Installation Guide for the complete terminal identification, wiring diagrams and mounting instructions.

Standalone Commissioning

Zoneconnex can be commissioned without a working home Wi-Fi network.

The TouchPoint LCD creates a local Wi-Fi access point, allowing the installer to connect directly and configure the system. Home Wi-Fi can be connected later.

Accessing Installer Mode

  1. Power on the indoor unit and Zoneconnex controller.
  2. Open System Info on the TouchPoint LCD.
  3. Tap the System information area eight times.
  4. Enter the authorised installer password.
  5. Open the anywAiR Zoneconnex mobile app.
  6. Select Continue as Installer.
  7. Follow the prompts to connect to the LCD local Wi-Fi access point.
  8. Scan the API Access QR code displayed on the LCD.
  9. Proceed with the installer configuration.
Installer Access: The default installer password documented in the September 2026 Installation Guide is 898989. This access is intended for authorised installers.

Zone Configuration

During commissioning, the installer can:

  • Configure between 1 and 10 zones.
  • Assign names to individual zones.
  • Set minimum and maximum damper openings.
  • Assign multiple dampers to a single zone.
  • Configure up to three relief zones.
  • Pair optional DROPLET sensors.
  • Select a primary temperature sensing zone where applicable.
  • Adjust damper stroke timing when required.
  • Configure current temperature display preferences.

By default, zone and damper assignments follow a one-to-one arrangement: Zone 1 to Damper 1, Zone 2 to Damper 2, and so on.

Airflow and Relief Zone Considerations

The installer must confirm adequate minimum airflow through the indoor unit under all expected zone operating conditions. Relief zones should be considered as part of the duct design and commissioning process.

The controller permits 0 to 3 relief zones, but selecting zero does not remove the requirement to maintain suitable system airflow.

Temperature Sensing

When installing the Zoneconnex LCD without an additional wall controller or primary DROPLET sensor, retain the indoor unit return-air sensor as the temperature sensing point.

A compatible UTY-RNRY series wall controller may operate alongside Zoneconnex. Operating changes are mirrored between the controllers, although zone control is not available through the UTY-RNRY.

Where a DROPLET is configured as the Primary Zone sensor, Zoneconnex can use this as the primary temperature sensing location.

Completing Commissioning

  1. Verify all configured zone names and assignments.
  2. Confirm damper operation and airflow limits.
  3. Check relief zone configuration.
  4. Verify paired sensors, where installed.
  5. Confirm temperature sensing and preferences.
  6. Open the installer menu.
  7. Select Finish Installation.
  8. Confirm the LCD returns to the normal home screen.
  9. Test normal operation and zone control.

Important: Use Finish Installation to save the completed configuration. Exiting without saving may result in configuration changes being lost.

Troubleshooting

IssueRecommended Checks
App cannot connect to systemConfirm home Wi-Fi connectivity, internet access and the TouchPoint LCD connection status. Restart the router and Zoneconnex if required.
Zone airflow not respondingUse Sync Zones. If the problem continues, arrange for the installer to check damper wiring, configuration and physical damper operation.
Current room temperature not displayedConfirm current temperature display has been enabled in the installer preferences. Individual zone temperature readings require optional DROPLET sensors.
Air conditioner cannot be controlledCheck the Notification and Alert screen for error codes. An indoor unit communication fault may prevent operation from both the LCD and app. Refer to qualified technical support.
Wi-Fi network not foundCheck the router is operating, verify wireless coverage and rescan available networks.
Zoneconnex not responding after setupConfirm the installation was completed using Finish Installation. Have the installer verify power, communications and saved settings.

System Errors and Notifications

The TouchPoint LCD includes a Notification and Alert screen where air conditioning system errors may be displayed.

Error codes are presented in the native two- or three-digit format to assist technical diagnosis.

Record the displayed error code, indoor unit model and relevant operating conditions before contacting Technical Support.

Frequently Asked Questions

Does Zoneconnex require home Wi-Fi to operate?

Home Wi-Fi is not required for local commissioning or normal touchscreen operation. Home internet connectivity is required for remote cloud-based app access.

Can I control each room independently?

You can independently enable or disable zones and adjust their airflow percentages. Individual zones do not have separate air conditioning temperature setpoints.

Can Zoneconnex be retrofitted?

Yes, where the indoor unit is compatible and the existing ductwork and damper specifications are suitable. An authorised installer must assess the existing installation.

Can multiple people use the mobile app?

Yes. The mobile app supports inviting and managing additional household users.

Can multiple systems be added to one app?

Yes. Multiple Zoneconnex systems can be managed through the app.

Does Zoneconnex support Google Home?

Google Home integration is not listed as a supported Zoneconnex feature in the supplied product documentation.

Are wireless temperature sensors included?

No. The TS-ZC1 DROPLET temperature and humidity sensors are optional accessories sold separately.

Important Product Information

  • Zoneconnex is an optional controller and is not included as standard with compatible ducted air conditioners.
  • Installation and servicing must be performed by qualified and authorised personnel.
  • Only compatible indoor units and approved accessories should be used.
  • Always isolate power before wiring or servicing.
  • System compatibility and duct design must be verified before installation.
  • Optional sensors are purchased separately.
  • Features and compatibility may change with future product or firmware updates.

Further Assistance

For product information, compatibility questions or technical assistance, contact GENERAL AIRSTAGE or your authorised air conditioning specialist.

GENERAL AIRSTAGE

Australia: 1300 882 201

Website:  www.generalairstage.com.au 

Email:  contact@generalairstage.com.au 

GENERAL AIRSTAGE | anywAiR Technology Zoneconnex | Model UTY-ZCAW1